By the Aquarium Boutique team · Updated November 2026
CO₂ is the single biggest lever in a planted aquarium. Carbon makes up close to half of a plant's dry mass, and under water it is almost always the nutrient that runs out first. This guide covers when you need it, how much to aim for, what equipment does what, how to set it up and how to fix the problems that come with it.
Do you actually need CO₂?
Light sets the demand. The more light you give, the faster plants try to grow and the more carbon they need. If the carbon is missing, growth stalls and algae use the light instead.
| Setup | Light | CO₂ | What to expect |
|---|---|---|---|
| Low-tech | Low, 6–7 h | Not needed | Slow growth, easy plants: Anubias, Cryptocoryne, mosses, ferns |
| Medium | Moderate, 7–8 h | Helps a lot | Most stem plants, denser growth, better colour |
| High-tech | Strong, 8 h | Required | Carpets, red plants, fast scapes. Without CO₂ you get algae |
If you run strong light and fight algae constantly, the fix is usually more stable CO₂ or less light, not another bottle of algae remover.
How much CO₂: the 20–30 mg/l target
Most injected tanks aim for about 20–30 mg/l during the photoperiod. Dissolved CO₂, KH and pH are linked by a simple relationship:
CO₂ (mg/l) = 3 × KH × 10(7 − pH)
| KH \ pH | 6.4 | 6.6 | 6.8 | 7.0 | 7.2 |
|---|---|---|---|---|---|
| 2 °dKH | 24 | 15 | 10 | 6 | 4 |
| 4 °dKH | 48 | 30 | 19 | 12 | 8 |
| 6 °dKH | 72 | 45 | 29 | 18 | 11 |
| 8 °dKH | 96 | 60 | 38 | 24 | 15 |
Values in mg/l. Use our free CO₂ calculator for your exact numbers. The table only holds when carbonates are the only buffer in the water: active soils, botanicals and pH-lowering products make it read too high.
The parts of a pressurised CO₂ system
| Part | What it does | Need it? |
|---|---|---|
| Cylinder | Stores liquid CO₂ under pressure | Yes |
| Regulator with needle valve | Drops cylinder pressure to a working pressure and lets you fine-tune the flow | Yes |
| Solenoid valve | Switches the gas on and off from a timer | Strongly recommended |
| Bubble counter | Makes the flow rate visible | Recommended |
| Check valve | Stops water running back into the regulator | Yes |
| CO₂-proof tubing | Standard airline hardens and leaks CO₂ over time | Yes |
| Diffuser or inline reactor | Dissolves the gas into the water | Yes |
| Drop checker | Shows by colour whether the level is low, right or too high | Yes |
Browse CO₂ systems, regulators, diffusers and accessories.
Which type of system?
| Type | Good for | Downsides |
|---|---|---|
| Yeast or citric acid DIY | Small tanks, trying CO₂ cheaply | Unstable output, cannot be switched off at night, frequent refills |
| Pressurised cylinder | Any tank you are serious about | Higher upfront cost. Cheapest and most stable in the long run |
| Liquid carbon | Low-tech tanks, mild algae pressure | Not a replacement for gas. Some plants (Vallisneria, some mosses) react badly |
Setting it up, step by step
- Secure the cylinder upright and fit the regulator with the needle valve closed.
- Connect bubble counter, check valve and diffuser with CO₂-proof tubing. The check valve goes between the tank and the regulator.
- Place the diffuser low in the tank, opposite the filter outlet or under the flow, so the mist is carried across the whole tank instead of rising straight up.
- Open the cylinder, set the working pressure your diffuser needs, then open the needle valve slowly.
- Start low, around one bubble per second for a 60–100 litre tank. Bubble counts are only a starting point: counters and tanks differ.
- Raise the rate a little every two or three days, watching the drop checker and the fish, until the checker is lime green at lights-on.
- Check every joint with soapy water. Most “my cylinder emptied in a month” stories are leaks.
When to switch CO₂ on and off
- On 1–2 hours before the lights. The level should already be at target when the light comes on. Plants do most of their uptake in the first hours.
- Off up to an hour before lights-out. Plants do not use CO₂ in the dark, so injecting at night only wastes gas and stresses fish.
- Keep it identical every day. Fluctuating CO₂ is the classic trigger for black beard algae and staghorn. Put the solenoid on a timer.
How to tell if the level is right
| Drop checker colour | Meaning | Action |
|---|---|---|
| Blue | Too little CO₂ | Raise the rate gradually or improve circulation |
| Green | About right | Leave it alone |
| Yellow | Too much | Reduce now and increase surface movement |
A drop checker lags by one to two hours, so read it as a trend. A second method is the pH drop: measure the pH of tank water that has stood in a glass for a day, then the pH in the tank at peak CO₂. A drop of about one full point corresponds to roughly 30 mg/l. Fish are the final authority: if they hang at the surface or breathe fast, cut the gas and add surface agitation immediately.
Troubleshooting
| Problem | Likely cause | Fix |
|---|---|---|
| Drop checker stays blue | Rate too low, poor circulation, too much surface turbulence, leak | Leak test, reposition diffuser, raise rate slowly |
| Fish gasping at the surface | CO₂ too high or too little oxygen | Turn gas down, raise the outlet to ripple the surface, water change if severe |
| Black beard or staghorn algae | Unstable CO₂ or dead spots in the flow | Fix timing and circulation first. See the algae guide |
| Bubble rate drifts | Cheap needle valve or working pressure too low | Raise working pressure, re-tune, consider a better regulator |
| Diffuser makes large bubbles | Clogged ceramic | Clean according to the maker's instructions or replace the disc |
| Livestock distress as the cylinder empties | End-of-tank dump on a single-stage regulator | Refill before the cylinder runs empty or use a dual-stage regulator |
| Water in the bubble counter line | Failed check valve | Replace it. They are wear parts |
CO₂ and oxygen are not opposites
A gently rippling surface costs you a little CO₂ and buys a lot of oxygen. Tanks with good oxygen tolerate higher CO₂ far better, so do not seal the surface flat to save gas. A surface skimmer and a filter outlet aimed slightly upwards are usually enough.
Quick reference
- Target 20–30 mg/l, lime-green drop checker at lights-on.
- On 1–2 h before lights, off up to 1 h before lights-out, same times every day.
- Change the rate in small steps, days apart.
- Match fertiliser to growth: more CO₂ and light means more nutrient demand. See our fertilizers.
You are welcome to quote or link to this guide. Questions about your own system? Write to us.